Arif Saltuk Ltd. Co.
Logo
     

Thermosel®/Controllers
Viscosity Determination At Elevated Temperatures

How It Solves A Difficult Problem
The difficulty with viscosity measurements of hot melts and liquids at elevated temperatures has been in maintaining accurate temperature control that is consistent from sample to sample, so that meaningful data could be obtained.

The Brookfield Thermosel® solves this problem by providing a stable, precisely controlled sample environment. This, together with the inherent accuracy of the Brookfield Viscometer, is fundamental to the Thermosel® System, which produces viscosity measurements that are not only accurate, but entirely reproducible.
Several factors contribute to the stable environment:
      - non-fluctuating temperature control
      - small sample volume and insulated sample chamber, which reduces temperature gradients with the sample
      - the rotating spindle, which acts as a built-in stirring device

  • Expedited research and QC procedures
  • Safe viscosity measurements of materials up to 300oC
  • Precise temperature control within ±0.5% of set point temperature
  • Excellent viscosity reproducibility
  • Small sample volume (8 to 13 ml)
  • Defined shear rates generated by coaxial cylinder geometry
  • Manual or programmable temperature control
  • Digital display of set point and Thermosel® temperature to 0.1oC or oF on controller
  • Temperature display switchable to oC or oF
  • Disposable sample chambers
  • DIN spindle geometry available

Various spindles are available for use with the Thermosel® System. Selection is determined by the viscosity measurement range that is required. Included with the Thermosel® are a thermo-container, safety guard and insulating cap, a proportional controller with RTD probe, one spindle (others available), one standard sample chamber, five disposable chambers, sample chamber holder, extraction tools, and an alignment bracket.

The Model 106 Programmable Temperature Controller allows up to 10 pre-programmed test steps which include both a set temperature and hold time at that temperature. This permits measurement of viscosity-temperature data for any test sample. The Model 75 Temperature Controller (single set point) is also available.

SPINDLE
VISCOSITY RANGE - Centipoise (mPa·s)
SHEAR RATE (sec-1)
SAMPLE VOLUME (mL)
LV SERIES VISCOMETERS
SC4-18
SC4-31
SC4-34
LVT LVT & LVDV-I+
LVDV-II+*
LVDV-III
1.32N**
0.34N
0.28N
9.5
10.0
9.5
5-10,000
50-100,000
100-200,000
3-10,000
30-100,000
60-200,000
1.5-30,000
15-300,000
30-600,000
1.2-30,000
12-300,000
24-600,000
RV SERIES VISCOMETERS
SC4-21
SC4-27
SC4-28
SC4-29
RVT
RVDV-E & RVDV-I+
RVDV-II+*
RVDV-III
0.93N**
0.34N
0.28N
0.25N
8.0
10.5
11.5
13.0
50-100,000
250-500,000
500-1,000,000
1,000-2,000,000
50-170,000
250-830,000
500-1,700,000
1,000-3,300,000
25-500,000
125-2,500,000
250-1,700,000
500-6,700,000
20-500,000
100-2,500,000
200-5,000,000
400-10,000,000
HA SERIES VISOMETERS
SC4-21
SC4-27
SC4-28
SC4-29
HAT
HADV-E & HADV-I+
HADV-II+*
HADV-III
0.93N**
0.34N
0.28N
0.25N
8.0
10.5
11.5
13.0
100-200,000
500-1,000,000
1,000-2,000,000
2,000-4,000,000
100-300,000
500-1,700,000
1,000-3,300,000
2,000-6,700,000
50-1,000,000
250-5,000,000
500-10,000,000
1,000-20,000,000
40-1,000,000
200-5,000,000
400-10,000,000
800-20,000,000
HB SERIES VISCOMETERS
SC4-21
SC4-27
SC4-28
SC4-29
HBT
HBDV-E & HBDV-I+
HBDV-II+*
HBDV-III
0.93N**
0.34N
0.28N
0.25N
8.0
10.5
11.5
13.0
400-800,000
2,000-4,000,000
4,000-8,000,000
8,000-16,000,000
400-1,300,000
2,000-6,700,000
4,000-13,300,000
8,000-80,000,000
200-4,000,000
1,000-20,000,000
2,000-40,000,000
4,000-80,000,000
160-4,000,000
800-20,000,000
1,600-40,000,000
3,2000-80,000,000